Offices Nationwide

Sound Transmissions
Paths can be interrupted by insulation and blocking air paths. A material's insulation is governed by mass, stiffening and damping...more

Sound Absorption
The loss of sound energy when sound waves come into contact with an absorbent material such as ceilings, walls, floors and other objects...more
Bury St. Edmunds - Sound Testing Part E - 01284 363 024
The office that covers this area is: Peterborough
Phone Number: 01284 363 024 Email: bury-st-edmunds@e2consultants.co.uk
Sound Insulation Testing for new or refurbished dwellings
In compliance with Part E of the Building Regulation in Bury St. Edmunds and nationwide, we actively encourage clients to seek our services at the earliest opportunity.
It is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
As part of our service in Bury St. Edmunds we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
Our consultants at Bury St. Edmunds can guide you through the process to ensure the best possible chance of achieving sound test passes.
E2 Consultants are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Call 01284 363 024 or email bury-st.-edmunds@e2consultants.co.uk to get a quote from one of Bury St. Edmunds consultants..
Pre-Completion Testing
The following table outlines the sets of tests that are required for new and converted properties.
Property Types | Test Requirements |
Dwelling-houses Including bungalows |
Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls |
Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls |
Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes |
To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
For further Sound Testing Part E information for your area, be sure to check out Sound-Testing-Bury-St.-Edmunds.co.uk.
Our other services include:
Sound Testing Part E can also be known as:
Commercial Sound Testing Part E, Commercial Part E Sound Testing, Part E Testing, Part E, Commercial Part E Sound Insulation Testing, Part E Sound Testing, Commercial Part E Testing, Commercial Part E, Part E Sound Insulation Testing, Sound Insulation Design Advice,


Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970