Offices Nationwide
Point of Reference
10 dBA is the sound level of normal human breathing. To put it into perspective, thunder is a whopping 120 dBA...more
Sound Privacy
Privacy describes the perceived sound reduction across a wall, a function of both sound insulation and background noise...more
Part L2A
Conservation of fuel and power in new builds other than dwellings
Caister-on-Sea - Part E Sound Insulation Testing - 01733 600 149
The office that covers this area is: Peterborough
Phone Number: 01733 600 149 Email: caister-on-sea@e2consultants.co.uk
Commercial_Sound_Testing_Part_E is sometimes referred to as Commercial Acoustic Testing, Commercial Sound & Acoustic Insulation Testing, Commercial Sound Testing, Commercial Sound Insulation Testing, Commercial Part E Compliance.
In Caister-on-Sea, E2 Consultants can deliver Sound Insulation Testing for new or refurbished dwellings in compliance with Part E of the Building Regulation.
As part of our service in Caister-on-Sea we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
We actively encourage clients to seek our services at the earliest opportunity as it is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
E2 Consultants in Caister-on-Sea are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Our consultants at Caister-on-Sea can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 01733 600 149 or email caister-on-sea@e2consultants.co.uk
Pre-Completion Testing - The following table outlines the sets of tests required for new and converted properties:
Property Types | Test Requirements |
Dwelling-houses Including bungalows |
Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls |
Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls |
Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes |
To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
For further Part E Sound Insulation Testing information for your area, be sure to check out Sound-Testing-Peterborough.co.uk.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970