Offices Nationwide
Sound Insulation
Two parameters describe sound insulation; Dw and Rw. Dw is the insulation between rooms. Rw is the lab-tested insulation of a wall/floor...more
Air Testing & Leakage
Our engineers use Thermal camera and extensive knowledge of buildings to help find leakage areas within the building and can advice of these.
Part L1B
Conservation of fuel and power in Existing Dwellings
Camborne - Domestic Sound Insulation Design Advice - 01752 687 017
The office that covers this area is: Plymouth
Phone Number: 01752 687 017 Email: camborne@e2consultants.co.uk
Sound Testing Part E is sometimes referred to as Domestic Sound & Acoustic Insulation Testing, Domestic Part E Compliance, Domestic Sound Testing, Domestic Acoustic Testing, Domestic Sound Insulation Testing.
E2 Consultants deliver Sound Insulation Testing for new or refurbished dwellings in compliance with Part E of the Building Regulation in Camborne and nationwide.
As part of our service in Camborne we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors. We actively encourage clients to seek our services at the earliest opportunity as it is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
Our consultants at Camborne can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 01752 687 017 or email camborne@e2consultants.co.uk
E2 Consultants in Camborne are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Pre-Completion Testing
The following table outlines the sets of tests that are required for New and Converted properties.
Property Types | Test Requirements |
Dwelling-houses Including bungalows | Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Rooms for Residential Purposes | To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
Flats with separating floor but not walls | Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls | Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne), and 6. bedroom/bedroom (wall, airborne) |