Privacy describes the perceived sound reduction across a wall, a function of both sound insulation and background noise...more
Reverberation Time
The reverberation time of a room is defined as the time it takes for sound to decay by 60 dB after an abrupt termination...more
Thermal Bridging And Airtightness
Enhanced Construction Details
Cromer - Commercial Part E Testing - 01733 600 149
The office that covers this area is: Peterborough
Phone Number: 01733 600 149 Email: cromer@e2consultants.co.uk
Commercial_Sound_Testing_Part_E is sometimes referred to as Commercial Sound Insulation Testing, Commercial Sound Testing, Commercial Sound & Acoustic Insulation Testing, Commercial Part E Compliance, Commercial Acoustic Testing.
E2 Consultants delivers Sound Insulation Testing for new or refurbished dwellings in compliance with Part E of the Building Regulation in Cromer and nationwide.
We actively encourage clients to seek our services at the earliest opportunity as it is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
As part of our service in Cromer we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
Our consultants at Cromer can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 01733 600 149 or email cromer@e2consultants.co.uk
E2 Consultants in Cromer are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Pre-Completion Testing - The following table outlines the sets of tests required for new and converted properties:
Property Types | Test Requirements |
Dwelling-houses Including bungalows |
Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls |
Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls |
Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes |
To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |