Offices Nationwide
Point of Reference
10 dBA is the sound level of normal human breathing. To put it into perspective, thunder is a whopping 120 dBA...more
Noise Disturbance
Building acoustics can help to mitigate the effects of noise disturbance which can have negative effects on your health and well-being...more
Part F
Means of Ventilation
Duxford - Domestic Part E - 01733 600 149
The office that covers this area is: Peterborough
Phone Number: 01733 600 149 Email: duxford@e2consultants.co.uk
Sound Testing Part E is sometimes referred to as Domestic Part E Compliance, Domestic Sound Insulation Testing, Domestic Sound & Acoustic Insulation Testing, Domestic Sound Testing, Domestic Acoustic Testing.
E2 Consultants deliver Sound Insulation Testing for new or refurbished dwellings in compliance with Part E of the Building Regulation in Duxford and nationwide.
We actively encourage clients to seek our services at the earliest opportunity as it is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
As part of our service in Duxford we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
E2 Consultants in Duxford are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Our consultants at Duxford can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 01733 600 149 or email duxford@e2consultants.co.uk
Pre-Completion Testing In Duxford - The following table outlines the sets of tests that are required for New and Converted properties.
Property Types | Test Requirements |
Dwelling-houses Including bungalows | Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Rooms for Residential Purposes | To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
Flats with separating floor but not walls | Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls | Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne), and 6. bedroom/bedroom (wall, airborne) |
For further Domestic Part E information for your area, be sure to check out Sound-Testing-Peterborough.co.uk.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970