Offices Nationwide
Environmental Noise Levels
The max exposure time at 85 dBA is 8 hours, at 110 dBA it's just 1 min 29 seconds. If exposed, limit the time and wear hearing protection...more
Noise Disturbance
Building acoustics can help to mitigate the effects of noise disturbance which can have negative effects on your health and well-being...more
Hadleigh - Party Floor Sound Insulation Testing - 020 3390 0301
The office that covers this area is: London
Phone Number: 020 3390 0301 Email: hadleigh@e2consultants.co.uk
Commercial_Sound_Testing is sometimes referred to as Commercial Sound Testing, Commercial Acoustic Testing, Commercial Sound Insulation Testing, Commercial Part E Compliance, Commercial Sound & Acoustic Insulation Testing.
At E2 Consultants in Hadleigh we offer nationwide acoustic consultancy, which involves comprehensive services across all aspects of noise measurement, assessment and control.
E2 Consultants have Party Floor Sound Insulation Testing consultants in Hadleigh specialising in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry professionals, local planning authorities and environmental services.
E2 Consultants' Party Floor Sound Insulation Testing consultants in Hadleigh have been involved in building and architectural projects at all stages of development, from the specification of the external building envelope and internal separating elements, through to pre-completion testing. Our expert advice has been sought after for different types of new build, refurbished and converted developments including residential, commercial, entertainment, leisure and hotels in addition to a wide variety of mixed-use developments.
We actively encourage clients in Hadleigh to seek our services at the earliest opportunity since the integration of acoustic issues into the overall design of a development should remove the need for costly revisions.
We believe that our Party Floor Sound Insulation Testing service delivery across the UK is second to none and that clients retain our expert services because of our continuous commitment to providing high quality and cost-effective advice. For a quote or more information, call one of our UK consultants in Hadleigh on 020 3390 0301 or email hadleigh@e2consultants.co.uk.
The onus is on the developer to perform pre-completion testing before the property can be 'released to market' and it is now an offence not to perform pre-completion testing.
In July 2003, the new Approved Document E 'Resistance to the Passage of Sound' (ADE 2003) of the Building Regulations came into force. This requires that new residential properties and rooms for residential purposes be tested (known as pre-completion testing) to demonstrate compliance with the explicit sound insulation performance requirements of ADE 2003.
Guidance in ADE 2003 on pre-completion testing indicates that tests should be carried out at a rate of one set of tests of each construction sub-group completed, whatever the size of the development and thereafter at least one set of tests every ten completions (assuming no failures).
We often advise property developers, contractors, housing associations and local authorities on the implications of ADE 2003. Advice is given on the materials and construction details for separating floors and walls and the key interfaces with other building elements. We also offer advice on the additional requirements of ADE 2003 including the control of reverberation in common areas and the performance of internal walls and floors. We are advising a number of clients on the practical application of RSDs as in some instances the option for construction are potentially reduced and construction costs may be significantly higher than those of a non-RSD structure.
Pre-Completion Testing
The table below outlines the sets of tests required for new and converted properties.
Property Types | Test Requirements |
Dwelling-houses Including bungalows |
Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls |
Normally, one set of tests should comprise of four individual SITs (2 x airborne, 2 x impact): 1. Living room (airborne), 2.Living room (Impact), 3. Bedroom (airborne) and 4. Bedroom (Impact) |
Flats with separating floor and walls |
Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes |
To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
For further Party Floor Sound Insulation Testing information for your area, be sure to check out Sound-Testing-London.co.uk.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970