Sound Insulation Testing for new or refurbished dwellings
In compliance with Part E of the Building Regulation in Invergordon and nationwide, we actively encourage clients to seek our services at the earliest opportunity.
It is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
As part of our service in Invergordon we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
Our consultants at Invergordon can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 0141 894 0107 or email invergordon@e2consultants.co.uk
E2 Consultants in Invergordon are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Pre-Completion Testing
The following table outlines the sets of tests that are required for new and converted properties.
Property Types | Test Requirements |
Dwelling-houses Including bungalows |
Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls |
Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls |
Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes |
To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Commercial Sound Testing Part E information for your area, be sure to check out Sound-Testing-Glasgow.co.uk.
Our other services include:
Commercial Sound Testing Part E can also be known as:
Commercial Part E Sound Insulation Testing, Commercial Part E Testing, Commercial Part E, Commercial Part E Sound Testing, Part E Sound Insulation Testing, Part E, Sound Testing Part E, Part E Sound Testing, Part E Testing, Sound Insulation Design Advice,


Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970