Offices Nationwide 

Liskeard - Air pressure testing - 01752 687 017

The office that covers this area is: Plymouth

Phone Number: 01752 687 017 Email: liskeard@e2consultants.co.uk

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness testing, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness tests, Domestic Air leakage testing.

Why E2 Consultants?

All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.

For a quote or for more information, call our air tightness / pressure testing consultants in Liskeard on 01752 687 017 or email us on Liskeard@e2consultants.co.uk

E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.

At E2 Consultants we offer Air Leakage Testing throughout Liskeard and surrounding areas. Our experienced air leakage testing consultants will also be happy to offer advice on the best ways to gain your target rating.

How Many Properties Need An Air Tightness Test?

According to Part L1a, an air pressure test needs to be undertaken on 50% of all dwelling types or three units of each type depending on which value is smaller. A block of flats is considered as a separate development and should be treated as such no matter on the number of blocks on the site. Furthermore, the testing should be done on the first batch of each type of dwelling to be completed. The need to test multiple versions of each type is to confirm the design and construction procedures are up to code according to Government regulations.

What Air Permeability Rating Do I Need?

Your air permeability rating resembles the amount of uncontrolled air that's leaking from the dwelling. A passing score in Liskeard is 10 m³/(h.m²). If the air test fails, we will help you identify where these leakage areas occur in the hope that a passing rate will be achieved following a re-test. The final target will be set by the design SAP Calculation (please contact us if you require one of these in Liskeard )

What Does An Air Leakage Test in Liskeard Involve?

An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results. Please note: an air test cannot be carried out if wind speed is more than 13mph. 3 metres per second is the ideal wind speed when undertaking an air test in Liskeard.

There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.

During an air test in Liskeard the pressure of the building will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut. Furniture will not be affected during the test, but smaller items such as paper must be held down or removed completely so they're not blown about.

When Should The Test Take Place?

The air leakage should be completed once the building is completed. All doors and windows in place, all skirting boards sealed, traps filled with water and any penetrations through the envelope of the building need to be sealed. Please find checklist within the downloads section of the website which provide a comprehensive list of requirements. People who follow this checklist have a much higher change of passing the air test first time.

For further Domestic Air Integrity Testing information for your area, be sure to check out Air-Testing-Plymouth.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100