Offices Nationwide 

Poynton - DSM Thermal Modelling - 0161 403 0129

The office that covers this area is: Manchester

Phone Number: 0161 403 0129 Email: poynton@e2consultants.co.uk

DSM_Thermal_Modelling is sometimes referred to as Thermal Modelling, DSM Thermal Modelling.

Poynton DSM & Thermal Modelling

Both SBEM & Dynamic Simulation Modelling (DSM) are approved methods for achieve compliance through energy assessments, however DSM provides a significantly more accurate and complex assessment. In the majority of cases DSM offers the design team significant benefits.

What is Dynamic Simulation Modelling

This service is similar to SBEM, Dynamic Simulation Modelling provides a calculation of the predicted energy consumed within a commercial building, through the modelling of the building’s features.

What’s involved?

The process involves taking designs and building specifications for a project, representing them in a 3D software model and running a simulation over a period of time to provide detailed results. Dynamic Simulation Modelling use historical weather information and accurate sun path analysis to run calculations at multiple stages of the year.

DSM allows for accurate investigation of the following areas:

  • Life Cycle Cost Analysis
  • Dynamic Thermal Modelling, Simulation & Calculation
  • Sun Cast and Solar Shading Analysis
  • HVAC Systems Simulation and Selection
  • Multi Zone Air Movement Simulation
  • Daylight Analysis
  • Natural and Electric Lighting Simulation
  • iSBEMs (A more accurate way of assessing part L2a & L2b compliance)

When used early in the design processes, calculations of predicted energy consumption through the modelling a building’s specifications can help in improving a buildings design and performance with the potential for reducing both development and operational costs. At later stages this way of modelling can be used in the testing, fine-tuning and implementation of design features, pushing them to their full potential.

E2 Consultants employ fully accredited Low Carbon Consultant with CIBSE and is qualified to Level 5. Please call us to discuss IES software and how it can enable you to design your building smarter, analyse sunpaths and natural ventilation options and minimise energy demand and CO2 emissions.

Our DSM quotes in Poynton can include:

  • Design Stage and As built Stage DSM Part L/F Compliant Calculations and BRUKL Report
  • Draft Energy Certificates
  • Energy Performance Certificate (EPC) / Building Energy Rating (BER)
  • BREEAM Assessment*

This means we can provide you with Level 5 EPCs, BRUKLs and Thermal Modelling as well as calculating CIBSE loads and reporting extensively on building performance.

The use of Dynamic Simulation Modelling can be used to help gain additional BREEAM credits for the following categories:

  • Glare Control
  • Thermal Comfort
  • Daylighting
  • Energy & CO2 Emissions
  • Low or Zero Carbon Technologies
E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100