Offices Nationwide 

Rothbury - Commercial Air Leakage Testing - 0191 633 0103

The office that covers this area is: Newcastle

Phone Number: 0191 633 0103 Email: rothbury@e2consultants.co.uk

Commercial_Air_Testing is sometimes referred to as Commercial AIR tests, Commercial AIR pressure tests, Commercial AIR tightness tests, Commercial AIR tightness testing, Commercial AIR pressure testing.

Commercial Air Leakage Testing in Rothbury

At E2 Consultants we offer Commercial Air Leakage Testing throughout Rothbury and surrounding areas. Our experienced Commercial Air Leakage Testing assessors will also be happy to offer advice on the best ways to gain your target rating. The number of properties to be tested should be in accordance with the following table:

E2 Consultants’ accredited consultants can help you comply with EPBD Article 9 and the Energy Performance of Buildings Regulations. Our expert consultants will undertake an assessment of the efficiency of your air conditioning system, reviewing sizing / capacity and offering advice on any improvements or alternative solutions. These solutions, if implemented, can in many instances reduce costs and thus pays for the inspection in the first year.

According to Part L1a, an air pressure test needs to be undertaken on 50% of all dwelling types or three units of each type depending on which value is smaller. A block of flats is considered as a separate development and should be treated as such no matter on the number of blocks on the site. Furthermore, the testing should be done on the first batch of each type of dwelling to be completed. The need to test multiple versions of each type is to confirm the design and construction procedures are up to code according to Government regulations.

The dwellings that make up the test sample are to be chosen by the Building Control Body (BCB) as well as the pressure tester. When selecting the dwellings it should be taken into account that half of the tests for each type should be scheduled during construction of the first 25% of that type. All results, including failures, should be reported back to the BCB. Undertaking the test early in the project means any adjustments can be made before the majority of construction is complete.

Envelope

Area (m2)

Leakage Rates (m3/hr at 50Pa)
5 7.5 10 15 20 25
2000 0.51 0.76 1.01 1.52 2.03 2.54
5000 1.27 1.90 2.54 3.80 5.07 6.34
7500 90 2.85 3.80 5.71 7.61 9.51
10000 2.54 3.80 5.07 7.61 10.14 12.68
12500 3.17 4.75 6.34 9.51 12.68 15.85
15000 3.80 5.71 7.61 11.41 15.21 19.02
20000 5.07 7.61 10.14 15.21 20.29 25.36

Commercial Air Leakage Testing is sometimes referred to as an Air Pressure Test, Envelope Test or an Air Permeability Test.

It is a requirement under the Building Regulations 2015 Part L that new dwellings in Rothbury must pass an Commercial Air Leakage Testing prior to occupation; this test certificate must be produced for the dwelling to be signed off by local Rothbury building control.

The report has all the details required by the regulations to indicate that a valid test has been performed.

To carry out such a test with accurate results, we require some general requirements to be made available at the time of the test:

1. SAP Design air pressure test figure

2. Electricity supply

3. Water supply to enable traps to be filled./p>

We will seal all of the intentional leakage areas in the house prior to testing. These include: fireplaces, extractor fans, exhaust fans, trickle vents and the odd uninstalled component. Everything else will have to stay 'as is' in the property.

It's strongly suggested that if you've never had a test before, that you review our air pressure / tightness pre-test checklist below.

Air Tightness Pre-Test Checklist

For a quote or for more information, call our Rothbury air tightness / pressure testing consultant on 0191 633 0103 or email rothbury@e2consultants.co.uk

For further Commercial Air Leakage Testing information for your area, be sure to check out Air-Testing-Newcastle.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100