Offices Nationwide
Air Testing & Leakage
Air Pressure Testing is not just for new-builds, it can be used to find leakage areas in existing buildings, improve the air tightness and improve/stop drafts..more
Sound Intensity
Sound intensity's measured in Decibels (dB). An logarithmic scale where an increase of 10 dB gives an apparent doubling of loudness...more
Shotley Gate - Workplace Noise - 01733 600 149
The office that covers this area is: Peterborough
Phone Number: 01733 600 149 Email: shotley-gate@e2consultants.co.uk
Workplace_Noise is sometimes referred to as Workplace Noise, Noise Risk Assessment at Work, Workplace Noise Risk Assessment.
Risk Assessments for Workplace Noise in Shotley Gate
All employers have a responsibility to carry out risk assessments in the workplace to identify any risk to health from exposure to noise. This applies to all work carried out by any employee working in a noisy environment or workplace.
Is it too loud?
If noise is intrusive, or you have to shout for a person to hear you less than 2 meters away, then you probably need a risk assessment. We can carry out the risk assessment in Shotley Gate and provide recommendations to demonstrate compliance with the control of noise at work regulations. The regulations state:
- Lower exposure action value of 80 Lepd (or weekly) LCpeak max 135 dB.
- Upper exposure action value of 85 Lepd daily (or weekly) LCpeak max 137 dB.
- Exposure limit value of 87 Lepd daily (or weekly) LCpeak max 140 dB.
However, both the upper exposure action value and the lower exposure action value do not take into account heating protection. Though the limit value does take into account hearing protection. This basically means that if you are below the 87dB then you need to take action to reduce the amount of exposure your Shotley Gate employees are exposed to.
What is the difference between the upper and lower exposure values? If you are below the lower exposure action value then there is no risk to the employees from noise exposure. You may still want to provide hearing protection for very noisy periods however.
Above the Lower Exposure Action Value
If you're above the lower exposure action value in Shotley Gate then you have to provide training, information and monitoring. Hearing protection may not be required at this stage but it is mandatory to provide the protection for those who feel it is necessary.
Above the Upper Exposure Action Value
Hearing protection zones are mandatory. Other monitoring may also be required for employees involved in working in the protection zone, this will include health monitoring of employees to ensure their hearing is not getting worse and no damage is being done. Hearing loss above this value can also indicate that the procedures in place may not be adequate.
Employers in Shotley Gate also have to take into consideration the right protection needed for the task without over protecting the employee. If the employee is over protected they may not hear vital alarms, vehicles and also feel isolated and be prone to accidents.
For further Workplace Noise information for your area, be sure to check out Sound-Testing-Peterborough.co.uk.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970