Commercial_Sound_Testing_Part_E is sometimes referred to as Commercial Part E Compliance, Commercial Sound Insulation Testing, Commercial Sound & Acoustic Insulation Testing, Commercial Sound Testing, Commercial Acoustic Testing.

Sound Insulation Testing for new or refurbished dwellings

In compliance with Part E of the Building Regulation in St. Austell and nationwide, we actively encourage clients to seek our services at the earliest opportunity.

It is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.

As part of our service in St. Austell we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.

E2 Consultants in St. Austell are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.

Our consultants at St. Austell can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 01752 687 017 or email st.-austell@e2consultants.co.uk

Pre-Completion Testing - The following table outlines the sets of tests required for new and converted properties:

Property Types Test Requirements

Dwelling-houses Including bungalows

Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall)

Flats with separating floor but not walls

Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact)

Flats with separating floor and walls

Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne)

Rooms for Residential Purposes

To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances.