Offices Nationwide
Air Testing & Leakage
Air Pressure Testing is not just for new-builds, it can be used to find leakage areas in existing buildings, improve the air tightness and improve/stop drafts..more
Air Testing
As part of thermographic surveys we can also use an air Pressure testing kit to depressurise the building and help detect any air leakage within the property..more
Tockenham - Commercial Fan Pressure Testing - 0239 366 0106
The office that covers this area is: Portsmouth
Phone Number: 0239 366 0106 Email: tockenham@e2consultants.co.uk
Commercial_Air_Testing is sometimes referred to as Commercial AIR tests, Commercial AIR pressure tests, Commercial AIR tightness testing, Commercial AIR pressure testing, Commercial AIR tightness tests.
Tockenham - Commercial Fan Pressure Testing
At E2 Consultants we provide Commercial Fan Pressure Testing for Tockenham. E2 Consultants' air consultants offer constructive advice on the best way to reach your target rating.
E2 Consultants’ accredited consultants can help you comply with EPBD Article 9 and the Energy Performance of Buildings Regulations. Our expert consultants will undertake an assessment of the efficiency of your air conditioning system, reviewing sizing / capacity and offering advice on any improvements or alternative solutions. These solutions, if implemented, can in many instances reduce costs and thus pays for the inspection in the first year.
According to Part L1a, an air pressure test needs to be undertaken on 50% of all dwelling types or three units of each type depending on which value is smaller. A block of flats is considered as a separate development and should be treated as such no matter on the number of blocks on the site. Furthermore, the testing should be done on the first batch of each type of dwelling to be completed. The need to test multiple versions of each type is to confirm the design and construction procedures are up to code according to Government regulations.
The dwellings that make up the test sample are to be chosen by the Building Control Body (BCB) as well as the pressure tester. When selecting the dwellings it should be taken into account that half of the tests for each type should be scheduled during construction of the first 25% of that type. All results, including failures, should be reported back to the BCB. Undertaking the test early in the project means any adjustments can be made before the majority of construction is complete.
Commercial Fan Pressure Testing can also be known as an Envelope Test, Air Pressure Test or Air Permeability Test.
It is a requirement under the Building Regulations 2015 Part L that new dwellings in Tockenham must pass an Commercial Fan Pressure Testing prior to occupation; this test certificate must be produced for the dwelling to be signed off by local Tockenham building control.
Envelope Area (m2) | Leakage Rates (m3/hr at 50Pa) | |||||
5 | 7.5 | 10 | 15 | 20 | 25 | |
2000 | 0.51 | 0.76 | 1.01 | 1.52 | 2.03 | 2.54 |
5000 | 1.27 | 1.90 | 2.54 | 3.80 | 5.07 | 6.34 |
7500 | 90 | 2.85 | 3.80 | 5.71 | 7.61 | 9.51 |
10000 | 2.54 | 3.80 | 5.07 | 7.61 | 10.14 | 12.68 |
12500 | 3.17 | 4.75 | 6.34 | 9.51 | 12.68 | 15.85 |
15000 | 3.80 | 5.71 | 7.61 | 11.41 | 15.21 | 19.02 |
20000 | 5.07 | 7.61 | 10.14 | 15.21 | 20.29 | 25.36 |
The report has all the details required by the regulations to indicate that a valid test has been performed.
To carry out such a test with accurate results, we require some general requirements to be made available at the time of the test:
1. SAP Design air pressure test figure
2. Electricity supply
3. Water supply to enable traps to be filled
We will seal all of the intentional leakage areas in the house prior to testing. These include: fireplaces, extractor fans, exhaust fans, trickle vents and the odd uninstalled component. Everything else will have to stay 'as is' in the property.
It's strongly suggested that if you've never had a test before, that you review our air pressure / tightness pre-test checklist below.
Air Tightness Pre-Test Checklist
For a quote or for more information, call our Tockenham air tightness / pressure testing consultant on 0239 366 0106 or email tockenham@e2consultants.co.uk
For further Commercial Fan Pressure Testing information for your area, be sure to check out Air-Testing-Portsmouth.co.uk.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970