Offices Nationwide
Air Testing & Leakage
Air Pressure Testing is not just for new-builds, it can be used to find leakage areas in existing buildings, improve the air tightness and improve/stop drafts..more
Sound Transmissions
Paths can be interrupted by insulation and blocking air paths. A material's insulation is governed by mass, stiffening and damping...more
Part E
Resistance of the Passage of Sound
Urmston - Thermal Comfort Calculation - 0161 403 0129
The office that covers this area is: Manchester
Phone Number: 0161 403 0129 Email: urmston@e2consultants.co.uk
DSM_Thermal_Modelling is sometimes referred to as DSM Thermal Modelling, Thermal Modelling.
DSM & Thermal Modelling
What is Dynamic Simulation Modelling in place
Both SBEM & Dynamic Simulation Modelling (DSM) are approved methods for achieve compliance through energy assessments, however DSM provides a significantly more accurate and complex assessment. In the majority of cases DSM offers the design team significant benefits.
This service is similar to SBEM, Dynamic Simulation Modelling provides a calculation of the predicted energy consumed within a commercial building, through the modelling of the building’s features.
What’s involved?
The process involves taking designs and building specifications for a project, representing them in a 3D software model and running a simulation over a period of time to provide detailed results. Dynamic Simulation Modelling use historical weather information and accurate sun path analysis to run calculations at multiple stages of the year.
When used early in the design processes, calculations of predicted energy consumption through the modelling a building’s specifications can help in improving a buildings design and performance with the potential for reducing both development and operational costs. At later stages this way of modelling can be used in the testing, fine-tuning and implementation of design features, pushing them to their full potential.
DSM allows for accurate investigation of the following areas:
- iSBEMs (A more accurate way of assessing part L2a & L2b compliance)
- Life Cycle Cost Analysis
- Dynamic Thermal Modelling, Simulation & Calculation
- HVAC Systems Simulation and Selection
- Daylight Analysis
- Natural and Electric Lighting Simulation
- Multi Zone Air Movement Simulation
- Sun Cast and Solar Shading Analysis
The use of Dynamic Simulation Modelling can be used to help gain additional BREEAM credits for the following categories:
- Daylighting
- Glare Control
- Thermal Comfort
- Energy & CO2 Emissions
- Low or Zero Carbon Technologies
E2 Consultants employ fully accredited Low Carbon Consultant with CIBSE and is qualified to Level 5. Please call us to discuss IES software and how it can enable you to design your building smarter, analyse sunpaths and natural ventilation options and minimise energy demand and CO2 emissions.
Our DSM quotes can include the following components:
- Energy Performance Certificate (EPC) / Building Energy Rating (BER)
- BREEAM Assessment*
- Design Stage and As built Stage DSM Part L/F Compliant Calculations and BRUKL Report
- Draft Energy Certificates
This means we can provide you with Level 5 EPCs, BRUKLs and Thermal Modelling as well as calculating CIBSE loads and reporting extensively on building performance.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970