10 dBA is the sound level of normal human breathing. To put it into perspective, thunder is a whopping 120 dBA...more

Noise Disturbance
Building acoustics can help to mitigate the effects of noise disturbance which can have negative effects on your health and well-being...more
Part L2A
Conservation of fuel and power in new builds other than dwellings

Woodnewton - Commercial Air Tightness Testing - 01733 600 149
The office that covers this area is: Peterborough
Phone Number: 01733 600 149 Email: woodnewton@e2consultants.co.uk
Woodnewton Commercial Air Tightness Testing Information
At E2 Consultants we provide air tests, air tightness tests and air pressure testing in Woodnewton and the surrounding areas.
We offer Commercial Air Tightness Testing throughout Woodnewton and surrounding areas. Our experienced Commercial Air Tightness Testing assessors will also be happy to offer advice on the best ways to gain your target rating. The number of properties to be tested should be in accordance with the following table:
Commercial Air Tightness Testing - Woodnewton
At E2 Consultants we offer Commercial Air Tightness Testing throughout Woodnewton and surrounding areas. Our experienced Commercial Air Tightness Testing assessors will also be happy to offer advice on the best ways to gain your target rating.
The dwellings that make up the test sample are to be chosen by the Building Control Body (BCB) as well as the pressure tester. When selecting the dwellings it should be taken into account that half of the tests for each type should be scheduled during construction of the first 25% of that type. All results, including failures, should be reported back to the BCB. Undertaking the test early in the project means any adjustments can be made before the majority of construction is complete.
According to Part L1a, an air pressure test needs to be undertaken on 50% of all dwelling types or three units of each type depending on which value is smaller. A block of flats is considered as a separate development and should be treated as such no matter on the number of blocks on the site. Furthermore, the testing should be done on the first batch of each type of dwelling to be completed. The need to test multiple versions of each type is to confirm the design and construction procedures are up to code according to Government regulations.
Commercial Air Tightness Testing can also be known as an Envelope Test, Air Pressure Test or Air Permeability Test.
It is a requirement under the Building Regulations 2015 Part L that new dwellings in Woodnewton must pass an Commercial Air Tightness Testing prior to occupation; this test certificate must be produced for the dwelling to be signed off by local Woodnewton building control.
Envelope Area (m2) | Leakage Rates (m3/hr at 50Pa) | |||||
5 | 7.5 | 10 | 15 | 20 | 25 | |
2000 | 0.51 | 0.76 | 1.01 | 1.52 | 2.03 | 2.54 |
5000 | 1.27 | 1.90 | 2.54 | 3.80 | 5.07 | 6.34 |
7500 | 90 | 2.85 | 3.80 | 5.71 | 7.61 | 9.51 |
10000 | 2.54 | 3.80 | 5.07 | 7.61 | 10.14 | 12.68 |
12500 | 3.17 | 4.75 | 6.34 | 9.51 | 12.68 | 15.85 |
15000 | 3.80 | 5.71 | 7.61 | 11.41 | 15.21 | 19.02 |
20000 | 5.07 | 7.61 | 10.14 | 15.21 | 20.29 | 25.36 |
The report has all the details required by the regulations to indicate that a valid test has been performed.
To carry out such a test with accurate results, we require some general requirements to be made available at the time of the test:
1. SAP Design air pressure test figure
2. Electricity supply
3. Water supply to enable traps to be filled
We will seal all of the intentional leakage areas in the house prior to testing. These include: fireplaces, extractor fans, exhaust fans, trickle vents and the odd uninstalled component. Everything else will have to stay 'as is' in the property.
It's strongly suggested that if you've never had a test before, that you review our air pressure / tightness pre-test checklist below.
Air Tightness Pre-Test Checklist
For a quote or for more information, call our Woodnewton air tightness / pressure testing consultant on 01733 600 149 or email woodnewton@e2consultants.co.uk
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Commercial Air Tightness Testing information for your area, be sure to check out Air-Testing-Peterborough.co.uk.
Our other services include:
Commercial Air Tightness Testing can also be known as:
Commercial Air Integrity Testing, Commercial House Leakage Testing, Commercial Air Pressure Testing, House Leakage Testing, Air Leakage Testing, Air Pressure Testing, Commercial Air Leakage Testing, Fan Pressure Testing, Commercial Air Testing, Commercial Fan Pressure Testing, Air Tightness Testing, Air Integrity Testing, Air Testing,


Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970