Offices Nationwide
Noise Disturbance
Building acoustics can help to mitigate the effects of noise disturbance which can have negative effects on your health and well-being...more
Sound Levels
Decibels (dB) are most commonly used as a measure of sound level, but they are also used in electronics, signals and communications...more
Part L2B
Conservation of fuel and power
Worcester - Commercial Part E - 01905 811 016
The office that covers this area is: Birmingham
Phone Number: 01905 811 016 Email: worcester@e2consultants.co.uk
Commercial_Sound_Testing_Part_E is sometimes referred to as Commercial Sound Insulation Testing, Commercial Sound Testing, Commercial Part E Compliance, Commercial Sound & Acoustic Insulation Testing, Commercial Acoustic Testing.
Sound Insulation Testing for new or refurbished dwellings
In compliance with Part E of the Building Regulation in Worcester and nationwide, we actively encourage clients to seek our services at the earliest opportunity.
It is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
As part of our service in Worcester we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
E2 Consultants in Worcester are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Our consultants at Worcester can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 01905 811 016 or email worcester@e2consultants.co.uk
Pre-Completion Testing - The following table outlines the sets of tests required for new and converted properties:
Property Types | Test Requirements |
Dwelling-houses Including bungalows |
Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls |
Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls |
Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes |
To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
For further Commercial Part E information for your area, be sure to check out Sound-Testing-Worcester.co.uk.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970