Offices Nationwide
Air Testing
As part of thermographic surveys we can also use an air Pressure testing kit to depressurise the building and help detect any air leakage within the property..more
Environmental Noise Levels
The max exposure time at 85 dBA is 8 hours, at 110 dBA it's just 1 min 29 seconds. If exposed, limit the time and wear hearing protection...more
Thermal Bridging And Airtightness
Enhanced Construction Details
Nottinghamshire - Domestic Carbon Emission Calc - 0114 368 0192
The office that covers this area is: Sheffield
The towns & cities that are covered within this county are:
Alverton, Annesley, Askham, Aslockton, Averham, Awsworth, Babworth, Balderton, Barnby Moor, Barnby in the Willows, Barton in Fabis, Bathley, Beckingham cum Saundby, Beeston, Besthorpe, Bestwood St Albans, Bilsthorpe, Bingham, Bleasby, Blidworth, Blyth, Bole, Bothamsall, Bradmore, Brinsley, Bulcote, Bunny, Burton Joyce, Calverton, Car Colston, Carburton, Carlton in Lindrick, Carlton on Trent, Caunton, Caythorpe, Clarborough, Clayworth, Clipston, Coddington, Collingham, Colwick, Cotgrave, Cromwell, Eakring, East Drayton, Eastwood, Edingley, Elston, Fardon, Flintham, Gamston, Gotham, Greasley, Harby, Hawksworth, Hickling, Holme, Hucknall, Keyworth, Kimberley, Kirkby in Ashfield, Kirton, Lound, Mansfield, Mapelbeck, Market Warsop, Newark, Norton, Nottingham, Oxton, Radcliffe on Trent, Rainworth, Retford, Southwell, Sutton in Ashfield, West Bridgford, Worksop,
Phone Number: 0114 368 0192 Email: nottinghamshire@e2consultants.co.uk
SAP Calculations is sometimes referred to as SAP Conversion Calcs, SAP Conversion Calc, SAP Conversion rating, Part L1B Compliance, SAP Conversion Assessment, SAP Conversion Calculations.
How Is A SAP Assessment Undertaken?
The SAP software will determine if a building complies with Building Regulations in Nottinghamshire using the information provided by the SAP assessment. This crucial information relates to the type of dwelling, floors, walls, the roof, windows, doors, lighting, renewable technologies, 'U' values, hot water and ventilation.
A SAP is done off-site but requires plans and drawings of the site in order to be calculated. Amongst other things, the SAP assessor will determine how good the thermal elements are in the floors and walls and how well heat passes through these elements - this is known as a 'U' value. A high 'U' value represents a high amount of heat lost - this is used in the SAP calculation.
What Is A SAP Calculation?
SAP calculations are the Government's Standard Assessment Procedure for Energy Ratings. In order to produce an On Construction EPC (Energy Performance Certificate) or a Predicted Energy Assessment (PEA), a SAP is required, as this is the calculation these certificates are based on.
A SAP rating represents the cost of energy required by a property over the course of a year with a score of 100 meaning there's no energy cost. This is calculated from lighting, heating, hot water systems, renewable technolgies used and the elements of structure. The higher the score, the lower the cost of running it.
Why Do I Need A SAP Calculation?
When changes are made to the heating, hot water provision or air conditioning/ventilation services, it is the responsibility of the builder to provide any On Construction EPCs upon completiong of a new home or conversion into fewer or more units.
You will need to provide information about energy efficiency in a Predicted Energy Assessment (PEA) if you are planning to sell the property before it has been built.
Under Part L of Building Regulations in Nottinghamshire, since 2006, any new dwellings or conversions need to have a SAP Calculation and Predicted EPC before any work can begin.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970