Air Testing is sometimes referred to as Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air tests, Domestic Air tightness tests, Domestic Air pressure tests, Domestic Air leakage testing.

When Should The Test Take Place?

For obvious reasons, an air pressure test is generally one of the last surveys to be undertaken once all the walls, windows, doors etc. are complete and sealed to stop any air escaping and prevent drafts through the property. The building envelope will also need to be completed.

What Air Permeability Rating Do I Need?

Your air permeability rating resembles the amount of uncontrolled air that's leaking from the dwelling. A passing score in Barnby in the Willows is 10 m³/(h.m²). If the air test fails, we will help you identify where these leakage areas occur in the hope that a passing rate will be achieved following a re-test. The final target will be set by the design SAP Calculation (please contact us if you require one of these in Barnby in the Willows )

What Does An Air Leakage Test in Barnby in the Willows Involve?

During an air test in Barnby in the Willows the pressure of the building will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut. Furniture will not be affected during the test, but smaller items such as paper must be held down or removed completely so they're not blown about.

Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in Barnby in the Willows. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.

Employees can still do their job inside a commercial or domestic building in Barnby in the Willows whilst the air test is being carried out, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building. There should be no outside access once the test has begun - which lasts for approximately 90 minutes, so plan accordingly.

Why E2 Consultants?

At E2 Consultants we offer Air Testing throughout Barnby in the Willows and surrounding areas. Our experienced air testing consultants will also be happy to offer advice on the best ways to gain your target rating.

For a quote or for more information, call our air tightness / pressure testing consultants in Barnby in the Willows on 0114 368 0192 or email us on Barnby_in_the_Willows@e2consultants.co.uk

All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.

E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.

How Many Properties Need An Air Tightness Test?

If you have 4 or less properties of the same type then only one test needs to be undertaken per type. If you have more than 4 but less than 40 dwellings of a type then you need at least two tests to be done on each type. Finally, if there are more than 40 properties of a particular type then at least 5% of each type needs to be tested UNLESS the first 5 get a passing score - then this can be dropped to just 2%.

For further Domestic Fan Pressure Testing information for your area, be sure to check out Air-Testing-Sheffield.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey