Offices Nationwide

Air Testing & Leakage
We have a checklist you can download for Air Leakage Testing. If you follow our air tightness checklist, this will improve your likelihood to achieve a pass!

Sound Insulation
Two parameters describe sound insulation; Dw and Rw. Dw is the insulation between rooms. Rw is the lab-tested insulation of a wall/floor...more
Part L1B
Conservation of fuel and power in Existing Dwellings

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.
Air Leaking Testing Across the UK
How Many Properties Need An Air Tightness Test?
If you have 4 or less properties of the same type then only one test needs to be undertaken per type. If you have more than 4 but less than 40 dwellings of a type then you need at least two tests to be done on each type. Finally, if there are more than 40 properties of a particular type then at least 5% of each type needs to be tested UNLESS the first 5 get a passing score - then this can be dropped to just 2%.
What Air Permeability Rating Do I Need?
A passing score in the UK is 10 m³/(h.m²) for an air permeability rating which resembles the amount of uncontrolled air that's leaking from the dwelling. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.
Do I Need An Air Leakage Test?
Planning your test in advance will help our experience air assessment team covering the UK to determine how many tests you'll need ahead of time per property and will be happy to offer advice on the best ways to gain your air permeability rating.
On a large plot of new houses that are built to a similar specification, only a sample of the houses will need to be air tested. This is outlined in Part L of Government building regulations.
All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, over a certain size, must have a passing air leakage certificate before the property can be sold.
What Does An Air Leakage Test Involve?
Employees can still do their job inside a commercial building in the UK, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building. There should be no outside access once the test has begun - which lasts for approximately 90 minutes, so plan accordingly.
During an air test in the UK the pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut. Furniture will not be affected during the test, but smaller items such as paper must be held down or removed completely so they're not blown about.
An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results. Please note: an air test cannot be carried out if wind speed is more than 13mph. 3 metres per second is the ideal wind speed when undertaking an air test in the UK.
When Should The Test Take Place?
For obvious reasons, an air pressure test is generally one of the last surveys to be undertaken once all the walls, windows, doors etc. are complete and sealed to stop any air escaping and prevent drafts through the property. The building envelope will also need to be completed.
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Domestic-Fan-Pressure-Testing information for your area, be sure to check out Air-Testing-.co.uk.
Our other services include:
Warning: Invalid argument supplied for foreach() in /data04/elite/public_html/Office.php on line 769
Domestic Fan Pressure Testing can also be known as:
Air Integrity Testing, Domestic Air Integrity Testing, Domestic House Leakage Testing, House Leakage Testing, Air Leakage Testing, Fan Pressure Testing, Air Tightness Testing, Air Testing, Domestic Air Testing, Domestic Air Pressure Testing, Air Pressure Testing, Domestic Air Leakage Testing, Domestic Air Tightness Testing,
Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970
In County C
Domestic Air pressure testing in Cambridgeshire, Domestic Air pressure testing in Carmarthenshire, Domestic Air pressure testing in Central, Domestic Air pressure testing in Channel Islands, Domestic Air pressure testing in Cheshire, Domestic Air pressure testing in Clackmannanshire, Domestic Air pressure testing in Conwy County, Domestic Air pressure testing in Cornwall, Domestic Air pressure testing in County Antrim, Domestic Air pressure testing in County Armagh, Domestic Air pressure testing in County Down, Domestic Air pressure testing in County Fermanagh, Domestic Air pressure testing in County Londonderry, Domestic Air pressure testing in County Tyrone, Domestic Air pressure testing in Cumbria,