Offices Nationwide
Sound Privacy
Privacy describes the perceived sound reduction across a wall, a function of both sound insulation and background noise...more
The Decibel Scale
Gives an approx of human perception of loudness. This is because the human ear has a logarithmic response to changes in sound level...more
Part L1B
Conservation of fuel and power in Existing Dwellings
Midhurst - Sound Testing Part E - 0239 366 0106
The office that covers this area is: Portsmouth
Phone Number: 0239 366 0106 Email: midhurst@e2consultants.co.uk
Sound Testing Part E is sometimes referred to as Domestic Sound Insulation Testing, Domestic Part E Compliance, Domestic Sound & Acoustic Insulation Testing, Domestic Acoustic Testing, Domestic Sound Testing.
E2 Consultants deliver Sound Insulation Testing for new or refurbished dwellings in compliance with Part E of the Building Regulation in Midhurst and nationwide.
We actively encourage clients to seek our services at the earliest opportunity as it is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
As part of our service in Midhurst we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
Our consultants at Midhurst can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 0239 366 0106 or email midhurst@e2consultants.co.uk
E2 Consultants in Midhurst are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Pre-Completion Testing
The following table outlines the sets of tests that are required for New and Converted properties.
Property Types | Test Requirements |
Dwelling-houses Including bungalows | Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Rooms for Residential Purposes | To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
Flats with separating floor but not walls | Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls | Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne), and 6. bedroom/bedroom (wall, airborne) |
For further Sound Testing Part E information for your area, be sure to check out Sound-Testing-Portsmouth.co.uk.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970