Offices Nationwide 

Telford - Air tightness tests - 0121 381 0129

The office that covers this area is: Birmingham

Phone Number: 0121 381 0129 Email: telford@e2consultants.co.uk

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air tests, Domestic Air leakage testing.

What Does An Air Leakage Test in Telford Involve?

There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.

Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in Telford. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.

Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.

Why E2 Consultants?

For a quote or for more information, call our air tightness / pressure testing consultants in Telford on 0121 381 0129 or email us on Telford@e2consultants.co.uk

At E2 Consultants we offer Air Permeability Testing throughout Telford and surrounding areas. Our experienced air permeability consultants will also be happy to offer advice on the best ways to gain your target rating.

All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.

E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.

What Air Permeability Rating Do I Need?

Your air permeability rating resembles the amount of uncontrolled air that's leaking from the dwelling. A passing score in Telford is 10 m³/(h.m²). If the air test fails, we will help you identify where these leakage areas occur in the hope that a passing rate will be achieved following a re-test. The final target will be set by the design SAP Calculation (please contact us if you require one of these in Telford )

When Should The Test Take Place?

The air leakage should be completed once the building is completed. All doors and windows in place, all skirting boards sealed, traps filled with water and any penetrations through the envelope of the building need to be sealed. Please find checklist within the downloads section of the website which provide a comprehensive list of requirements. People who follow this checklist have a much higher change of passing the air test first time.

How Many Properties Need An Air Tightness Test?

The number of tests required are as follows:

  • 4 or less properties of the same type: one test needed per type
  • More than 4 but less than 40 dwellings of a type: at least two tests of each type
  • More than 40 properties of a type: 5% of each type UNLESS the first 5 get a passing score - then this can be dropped to just 2%

For further Domestic Air Pressure Testing information for your area, be sure to check out Air-Testing-Birmingham.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100