Offices Nationwide 

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.

Air Leaking Testing Across the UK

When Should The Test Take Place?

A building envelope will need to be completed before the air test takes place - which should be one of the last surveys undertaken once all the walls, windows, doors etc. are complete and sealed. This ensures no air will escape and prevent drafts through the property which will in-turn improve your air permeability score.

What Air Permeability Rating Do I Need?

The air tightness rating of a property is not a fixed figure. This is set by the design SAP Calculation carried out (please contact us if you also require a SAP Calculation in the UK ). However the worst acceptable standard for air tightness is 10 m³/(h.m²) which resembles the amount of uncontrolled air that's leaking from the dwelling. However this does not mean that it would pass the SAP Calculations Design Air Permeability standard. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.

What Does An Air Leakage Test in the UK Involve?

Employees can still do their job inside a commercial or domestic building in the UK whilst the air test is being carried out, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building. There should be no outside access once the test has begun - which lasts for approximately 90 minutes, so plan accordingly.

Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.

Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.

Why E2 Consultants?

At E2 Consultants we offer Air Pressure Testing throughout the UK and surrounding areas. Our experienced air pressure testing consultants will also be happy to offer advice on the best ways to gain your target rating.

E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.

For a quote or for more information, call our air tightness / pressure testing consultants in the UK on 0800 043 8100 or email us on @e2consultants.co.uk

All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.

How Many Properties Need An Air Tightness Test?

According to Part L1a, an air pressure test needs to be undertaken on 50% of all dwelling types or three units of each type depending on which value is smaller. A block of flats is considered as a separate development and should be treated as such no matter on the number of blocks on the site. Furthermore, the testing should be done on the first batch of each type of dwelling to be completed. The need to test multiple versions of each type is to confirm the design and construction procedures are up to code according to Government regulations.

For further Domestic-Air-Pressure-Testing information for your area, be sure to check out Air-Testing-.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100

In Area N

Domestic Air leakage testing in Nailsea, Domestic Air leakage testing in Nailsworth, Domestic Air leakage testing in Nairn, Domestic Air leakage testing in Nantwich, Domestic Air leakage testing in Narberth, Domestic Air leakage testing in Nayland, Domestic Air leakage testing in Neath, Domestic Air leakage testing in Needham Market, Domestic Air leakage testing in Nelson, Domestic Air leakage testing in Neston, Domestic Air leakage testing in Netherton, Domestic Air leakage testing in New Mills, Domestic Air leakage testing in New Milton, Domestic Air leakage testing in New Romney, Domestic Air leakage testing in New Southgate, Domestic Air leakage testing in Newark, Domestic Air leakage testing in Newbury, Domestic Air leakage testing in Newcastle, Domestic Air leakage testing in Newcastle Emlyn, Domestic Air leakage testing in Newcastle upon Tyne, Domestic Air leakage testing in Newchapel, Domestic Air leakage testing in Newcross, Domestic Air leakage testing in Newent, Domestic Air leakage testing in Newhaven, Domestic Air leakage testing in Newlyn, Domestic Air leakage testing in Newmarket, Domestic Air leakage testing in Newnham, Domestic Air leakage testing in Newport, Domestic Air leakage testing in Newport, Domestic Air leakage testing in Newport, Domestic Air leakage testing in Newport on Tay, Domestic Air leakage testing in Newport Pagnell, Domestic Air leakage testing in Newquay, Domestic Air leakage testing in Newry, Domestic Air leakage testing in Newton, Domestic Air leakage testing in Newton Abbot, Domestic Air leakage testing in Newton Aycliffe, Domestic Air leakage testing in Newton le Willows, Domestic Air leakage testing in Newton Stewart, Domestic Air leakage testing in Newtown, Domestic Air leakage testing in Newtownabbey, Domestic Air leakage testing in Newtownards, Domestic Air leakage testing in Normanton, Domestic Air leakage testing in North Berwick, Domestic Air leakage testing in North East, Domestic Air leakage testing in North Finchley, Domestic Air leakage testing in North Kenningston, Domestic Air leakage testing in North Walsham, Domestic Air leakage testing in Northallerton, Domestic Air leakage testing in Northampton, Domestic Air leakage testing in Northern Ireland, Domestic Air leakage testing in Northleach, Domestic Air leakage testing in Northolt, Domestic Air leakage testing in Northwich, Domestic Air leakage testing in Norton, Domestic Air leakage testing in Norwich, Domestic Air leakage testing in Norwood, Domestic Air leakage testing in Nottingham, Domestic Air leakage testing in Nottinghill, Domestic Air leakage testing in Nuneaton, Domestic Air leakage testing in Nutfield,