Offices Nationwide
Environmental Noise Levels
The max exposure time at 85 dBA is 8 hours, at 110 dBA it's just 1 min 29 seconds. If exposed, limit the time and wear hearing protection...more
Sound Privacy
Privacy describes the perceived sound reduction across a wall, a function of both sound insulation and background noise...more
West Ham - Part E - 020 3390 0301
The office that covers this area is: London
Phone Number: 020 3390 0301 Email: west-ham@e2consultants.co.uk
Commercial_Sound_Testing_Part_E is sometimes referred to as Commercial Part E Compliance, Commercial Sound Testing, Commercial Sound Insulation Testing, Commercial Sound & Acoustic Insulation Testing, Commercial Acoustic Testing.
In West Ham, E2 Consultants can deliver Sound Insulation Testing for new or refurbished dwellings in compliance with Part E of the Building Regulation.
As part of our service in West Ham we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
We actively encourage clients to seek our services at the earliest opportunity as it is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
E2 Consultants in West Ham are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Our consultants at West Ham can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 020 3390 0301 or email west-ham@e2consultants.co.uk
Pre-Completion Testing - The following table outlines the sets of tests that are required for new and converted properties.
Property Types | Test Requirements |
Dwelling-houses Including bungalows |
Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls |
Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls |
Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes |
To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
For further Part E information for your area, be sure to check out Sound-Testing-London.co.uk.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970