Offices Nationwide

Sound Intensity
Sound intensity's measured in Decibels (dB). An logarithmic scale where an increase of 10 dB gives an apparent doubling of loudness...more

Environmental Noise Levels
The max exposure time at 85 dBA is 8 hours, at 110 dBA it's just 1 min 29 seconds. If exposed, limit the time and wear hearing protection...more
Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.
Air Leaking Testing Across the UK
What Air Permeability Rating Do I Need?
A passing score in the UK is 10 m³/(h.m²) for an air permeability rating which resembles the amount of uncontrolled air that's leaking from the dwelling. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.
How Many Properties Need An Air Tightness Test?
The number of tests required are as follows:
- 4 or less properties of the same type: one test needed per type
- More than 4 but less than 40 dwellings of a type: at least two tests of each type
- More than 40 properties of a type: 5% of each type UNLESS the first 5 get a passing score - then this can be dropped to just 2%
Do I Need An Air Leakage Test?
All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, over a certain size, must have a passing air leakage certificate before the property can be sold.
On a large plot of new houses that are built to a similar specification, only a sample of the houses will need to be air tested. This is outlined in Part L of Government building regulations.
We offer air leakage testing throughout the UK where our experienced assessors will be happy to offer advice on the best ways to gain your air permeability rating. Planning your test in advance will help us determine how many tests you'll need ahead of time per property.
When Should The Test Take Place?
A building envelope will need to be completed before the air test takes place - which should be one of the last surveys undertaken once all the walls, windows, doors etc. are complete and sealed. This ensures no air will escape and prevent drafts through the property which will in-turn improve your air permeability score.
What Does An Air Leakage Test Involve?
Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.
Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.
Employees can still do their job inside a commercial building in the UK, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building. There should be no outside access once the test has begun - which lasts for approximately 90 minutes, so plan accordingly.
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further House-Leakage-Testing information for your area, be sure to check out Air-Testing-.co.uk.
Our other services include:
Warning: Invalid argument supplied for foreach() in /data04/elite/public_html/Office.php on line 769
House Leakage Testing can also be known as:
Domestic Fan Pressure Testing, Domestic House Leakage Testing, Domestic Air Leakage Testing, Fan Pressure Testing, Air Integrity Testing, Air Testing, Domestic Air Tightness Testing, Domestic Air Pressure Testing, Domestic Air Integrity Testing, Air Leakage Testing, Air Tightness Testing, Domestic Air Testing, Air Pressure Testing,
Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970
In Area I
Domestic Air tightness testing in Ibstock, Domestic Air tightness testing in Ilchester, Domestic Air tightness testing in Ilford, Domestic Air tightness testing in Ilfracombe, Domestic Air tightness testing in Ilkeston, Domestic Air tightness testing in Ilkley, Domestic Air tightness testing in Ilminster, Domestic Air tightness testing in Immingham, Domestic Air tightness testing in Ince-in-Makerfield, Domestic Air tightness testing in Ingatestone, Domestic Air tightness testing in Ingleton, Domestic Air tightness testing in Inkberrow, Domestic Air tightness testing in Innerleithen, Domestic Air tightness testing in Insch, Domestic Air tightness testing in Inveraray, Domestic Air tightness testing in Invergordon, Domestic Air tightness testing in Inverkeithing, Domestic Air tightness testing in Inverness, Domestic Air tightness testing in Inverurie, Domestic Air tightness testing in Ipswich, Domestic Air tightness testing in Irchester, Domestic Air tightness testing in Ireland, Domestic Air tightness testing in Irlam, Domestic Air tightness testing in Irthlingborough, Domestic Air tightness testing in Irvine, Domestic Air tightness testing in Isle of Arran, Domestic Air tightness testing in Isle of Scilly, Domestic Air tightness testing in Isle of Skye, Domestic Air tightness testing in Isleworth, Domestic Air tightness testing in Islington, Domestic Air tightness testing in Iver, Domestic Air tightness testing in Ivybridge,