Offices Nationwide
Air Testing & Leakage
Our engineers use Thermal camera and extensive knowledge of buildings to help find leakage areas within the building and can advice of these.
Air Testing & Leakage
We can offer additional services at discounted rates along side our tests! These are Sound Testing and Part F. Ask our Consultants for more
Part F
Means of Ventilation
Queensbury - Air tightness testing - 01924 578 029
The office that covers this area is: Wakefield
Phone Number: 01924 578 029 Email: queensbury@e2consultants.co.uk
Air Testing is sometimes referred to as Domestic Air tightness testing, Domestic Air tests, Domestic Air pressure testing, Domestic Air leakage testing, Domestic Air pressure tests, Domestic Air tightness tests.
When Should The Test Take Place?
A building envelope will need to be completed before the air test takes place - which should be one of the last surveys undertaken once all the walls, windows, doors etc. are complete and sealed. This ensures no air will escape and prevent drafts through the property which will in-turn improve your air permeability score.
What Air Permeability Rating Do I Need?
A passing score in Queensbury is 10 m³/(h.m²) for an air permeability rating which resembles the amount of uncontrolled air that's leaking from the dwelling. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.
How Many Properties Need An Air Tightness Test?
If you have 4 or less properties of the same type then only one test needs to be undertaken per type. If you have more than 4 but less than 40 dwellings of a type then you need at least two tests to be done on each type. Finally, if there are more than 40 properties of a particular type then at least 5% of each type needs to be tested UNLESS the first 5 get a passing score - then this can be dropped to just 2%.
What Does An Air Leakage Test Involve?
There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.
Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.
An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results. Please note: an air test cannot be carried out if wind speed is more than 13mph. 3 metres per second is the ideal wind speed when undertaking an air test in Queensbury.
Do I Need An Air Leakage Test?
We offer air leakage testing throughout Queensbury where our experienced assessors will be happy to offer advice on the best ways to gain your air permeability rating. Planning your test in advance will help us determine how many tests you'll need ahead of time per property.
Part L of the Government building regulations explains that on a large plot of new houses that are built to a similar specification, only a sample of the houses will need to be air tested.
Domestic properties and commercial buildings over a certain size must have a passing air leakage certificate before the property can be handed over following a sale. All new buildings in England and Wales have had this requirement since 2006 and in Scotland this has been mandatory since 2010.
For further Air Integrity Testing information for your area, be sure to check out Air-Testing-Wakefield.co.uk.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970