Offices Nationwide 

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.

Air Leaking Testing Across the UK

Why E2 Consultants?

For a quote or for more information, call our air tightness / pressure testing consultants in the UK on 0800 043 8100 or email us on @e2consultants.co.uk

All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.

E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.

At E2 Consultants we offer Air Pressure Testing throughout the UK and surrounding areas. Our experienced air pressure testing consultants will also be happy to offer advice on the best ways to gain your target rating.

How Many Properties Need An Air Tightness Test?

According to Part L1a, an air pressure test needs to be undertaken on 50% of all dwelling types or three units of each type depending on which value is smaller. A block of flats is considered as a separate development and should be treated as such no matter on the number of blocks on the site. Furthermore, the testing should be done on the first batch of each type of dwelling to be completed. The need to test multiple versions of each type is to confirm the design and construction procedures are up to code according to Government regulations.

What Does An Air Leakage Test in the UK Involve?

An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results. Please note: an air test cannot be carried out if wind speed is more than 13mph. 3 metres per second is the ideal wind speed when undertaking an air test in the UK.

During an air test in the UK the pressure of the building will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut. Furniture will not be affected during the test, but smaller items such as paper must be held down or removed completely so they're not blown about.

There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.

When Should The Test Take Place?

A building envelope will need to be completed before the air test takes place - which should be one of the last surveys undertaken once all the walls, windows, doors etc. are complete and sealed. This ensures no air will escape and prevent drafts through the property which will in-turn improve your air permeability score.

What Air Permeability Rating Do I Need?

The air tightness rating of a property is not a fixed figure. This is set by the design SAP Calculation carried out (please contact us if you also require a SAP Calculation in the UK ). However the worst acceptable standard for air tightness is 10 m³/(h.m²) which resembles the amount of uncontrolled air that's leaking from the dwelling. However this does not mean that it would pass the SAP Calculations Design Air Permeability standard. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.

For further Air-Integrity-Testing information for your area, be sure to check out Air-Testing-.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100

In Area T

Domestic Air tightness tests in Tadcaster, Domestic Air tightness tests in Tadley, Domestic Air tightness tests in Tadworth, Domestic Air tightness tests in Tain, Domestic Air tightness tests in Talgarth, Domestic Air tightness tests in Tamworth, Domestic Air tightness tests in Tanwood, Domestic Air tightness tests in Tarporley, Domestic Air tightness tests in Taunton, Domestic Air tightness tests in Tavistock, Domestic Air tightness tests in Teddington, Domestic Air tightness tests in Teignmouth, Domestic Air tightness tests in Telford, Domestic Air tightness tests in Tenby, Domestic Air tightness tests in Tenterden, Domestic Air tightness tests in Tetbury, Domestic Air tightness tests in Tewkesbury, Domestic Air tightness tests in Thame, Domestic Air tightness tests in Thamesmead, Domestic Air tightness tests in Thatcham, Domestic Air tightness tests in Thaxted, Domestic Air tightness tests in The midlands, Domestic Air tightness tests in Thetford, Domestic Air tightness tests in Thirsk, Domestic Air tightness tests in Thornbury, Domestic Air tightness tests in Thornton-Clevelyes, Domestic Air tightness tests in Thrapston, Domestic Air tightness tests in Thurso, Domestic Air tightness tests in Tibberton, Domestic Air tightness tests in Tidcombe, Domestic Air tightness tests in Tidworth, Domestic Air tightness tests in Tilbury, Domestic Air tightness tests in Tillicoultry, Domestic Air tightness tests in Tintagel, Domestic Air tightness tests in Tipton, Domestic Air tightness tests in Tiverton, Domestic Air tightness tests in Tobermory, Domestic Air tightness tests in Tockenham, Domestic Air tightness tests in Toddington, Domestic Air tightness tests in Todmorden, Domestic Air tightness tests in Tonbridge, Domestic Air tightness tests in Tongham, Domestic Air tightness tests in Tonypandy, Domestic Air tightness tests in Tooting, Domestic Air tightness tests in Torpoint, Domestic Air tightness tests in Torquay, Domestic Air tightness tests in Torrington, Domestic Air tightness tests in Totnes, Domestic Air tightness tests in Tottenham, Domestic Air tightness tests in Totton, Domestic Air tightness tests in Towcester, Domestic Air tightness tests in Trafford Park, Domestic Air tightness tests in Tredegar, Domestic Air tightness tests in Tregaron, Domestic Air tightness tests in Treharris, Domestic Air tightness tests in Trentham, Domestic Air tightness tests in Treorchy, Domestic Air tightness tests in Tring, Domestic Air tightness tests in Troon, Domestic Air tightness tests in Trowbridge, Domestic Air tightness tests in Truro, Domestic Air tightness tests in Tunbridge Wells, Domestic Air tightness tests in Tutbury, Domestic Air tightness tests in Tutnall, Domestic Air tightness tests in Twickenham, Domestic Air tightness tests in Twycross, Domestic Air tightness tests in Tyldesley, Domestic Air tightness tests in Tyne, Domestic Air tightness tests in Tynemouth, Domestic Air tightness tests in Tywyn,