Offices Nationwide 

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.

Air Leaking Testing Across the UK

What Air Permeability Rating Do I Need?

A passing score in the UK is 10 m³/(h.m²) for an air permeability rating which resembles the amount of uncontrolled air that's leaking from the dwelling. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.

What Does An Air Leakage Test Involve?

Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.

There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.

Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.

How Many Properties Need An Air Tightness Test?

The number of tests required are as follows:

  • 4 or less properties of the same type: one test needed per type
  • More than 4 but less than 40 dwellings of a type: at least two tests of each type
  • More than 40 properties of a type: 5% of each type UNLESS the first 5 get a passing score - then this can be dropped to just 2%

When Should The Test Take Place?

A building envelope will need to be completed before the air test takes place - which should be one of the last surveys undertaken once all the walls, windows, doors etc. are complete and sealed. This ensures no air will escape and prevent drafts through the property which will in-turn improve your air permeability score.

Do I Need An Air Leakage Test?

All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, over a certain size, must have a passing air leakage certificate before the property can be sold.

On a large plot of new houses that are built to a similar specification, only a sample of the houses will need to be air tested. This is outlined in Part L of Government building regulations.

We offer air leakage testing throughout the UK where our experienced assessors will be happy to offer advice on the best ways to gain your air permeability rating. Planning your test in advance will help us determine how many tests you'll need ahead of time per property.

For further Air-Integrity-Testing information for your area, be sure to check out Air-Testing-.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100

In Area G

Domestic Air leakage testing in Gainsborough, Domestic Air leakage testing in Galashiels, Domestic Air leakage testing in Gamston, Domestic Air leakage testing in Garston, Domestic Air leakage testing in Gateshead, Domestic Air leakage testing in Gaydon, Domestic Air leakage testing in Gerrards Cross, Domestic Air leakage testing in Gillingham, Domestic Air leakage testing in Gillingham, Domestic Air leakage testing in Glasgow, Domestic Air leakage testing in Glastonbury, Domestic Air leakage testing in Glossop, Domestic Air leakage testing in Gloucester, Domestic Air leakage testing in Godalming, Domestic Air leakage testing in Godmanchester, Domestic Air leakage testing in Godstone, Domestic Air leakage testing in Golborne, Domestic Air leakage testing in Golders Green, Domestic Air leakage testing in Goole, Domestic Air leakage testing in Goring, Domestic Air leakage testing in Gorseinon, Domestic Air leakage testing in Gosforth, Domestic Air leakage testing in Gosport, Domestic Air leakage testing in Gotham, Domestic Air leakage testing in Gourock, Domestic Air leakage testing in Graet Ayton, Domestic Air leakage testing in Grafton, Domestic Air leakage testing in Grange over Sands, Domestic Air leakage testing in Grangemouth, Domestic Air leakage testing in Grantham, Domestic Air leakage testing in Grantown on Spey, Domestic Air leakage testing in Grassendale, Domestic Air leakage testing in Grassinton, Domestic Air leakage testing in Gravesend, Domestic Air leakage testing in Grays, Domestic Air leakage testing in Greasley, Domestic Air leakage testing in Great Missenden, Domestic Air leakage testing in Great Yarmouth, Domestic Air leakage testing in Greater London, Domestic Air leakage testing in Greenford, Domestic Air leakage testing in Greenock, Domestic Air leakage testing in Greenwich, Domestic Air leakage testing in Grimley, Domestic Air leakage testing in Grimsby, Domestic Air leakage testing in Grindley, Domestic Air leakage testing in Guildford,