SAP Calculations Across the UK

How Is A SAP Assessment Undertaken?

Amongst other things, the SAP assessor will determine how good the thermal elements are in the floors and walls as well as how well heat passes through these elements - this is known as a 'U' value. A high 'U' value represents a high amount of heat lost - this is used in the SAP calculation which is done off-site but requires plans and drawings of the site in order to be calculated.

The SAP software will determine if a building complies with Building Regulations in the UK using the information provided by the SAP assessment. This crucial information relates to the type of dwelling, floors, walls, the roof, windows, doors, lighting, renewable technologies, 'U' values, hot water and ventilation.

Why Do I Need A SAP Calculation?

You will need to provide information about energy efficiency in a Predicted Energy Assessment (PEA) if you are planning to sell the property before it has been built.

Under Part L of Building Regulations in the UK, since 2006, any new dwellings or conversions need to have a SAP Calculation and Predicted EPC before any work can begin.

When changes are made to the heating, hot water provision or air conditioning/ventilation services, it is the responsibility of the builder to provide any On Construction EPCs upon completiong of a new home or conversion into fewer or more units.

What Is A SAP Calculation?

A SAP rating represents the cost of energy required by a property over the course of a year with a score of 100 meaning there's no energy cost. This is calculated from lighting, heating, hot water systems, renewable technolgies used and the elements of structure. The higher the score, the lower the cost of running it.

A SAP calculation, the Government's Standard Assessment Procedure for Energy Ratings, is required to produce an On Construction EPC (Energy Performance Certificate) or a Predicted Energy Assessment (PEA).

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100

In Area O

SAP Conversion Calculations in Oadby, SAP Conversion Calculations in Oakamoor, SAP Conversion Calculations in Oakham, SAP Conversion Calculations in Oban, SAP Conversion Calculations in Ockham, SAP Conversion Calculations in Oddingley, SAP Conversion Calculations in Okehampton, SAP Conversion Calculations in Old Warden, SAP Conversion Calculations in Old Windsor, SAP Conversion Calculations in Oldbury, SAP Conversion Calculations in Oldham, SAP Conversion Calculations in Oldmeldrum, SAP Conversion Calculations in Olney, SAP Conversion Calculations in Omagh, SAP Conversion Calculations in Once Brewed, SAP Conversion Calculations in Ongar, SAP Conversion Calculations in Orford, SAP Conversion Calculations in Orkney, SAP Conversion Calculations in Ormskirk, SAP Conversion Calculations in Orpington, SAP Conversion Calculations in Ossett, SAP Conversion Calculations in Oswaldtwistle, SAP Conversion Calculations in Oswestry, SAP Conversion Calculations in Otley, SAP Conversion Calculations in Otley, SAP Conversion Calculations in Ottery St. Mary, SAP Conversion Calculations in Oulton, SAP Conversion Calculations in Oundle, SAP Conversion Calculations in Outwood, SAP Conversion Calculations in Overbury, SAP Conversion Calculations in Oxford, SAP Conversion Calculations in Oxted, SAP Conversion Calculations in Oxton,